TY - BOOK AU - RAJNEESH Kant TI - Study of micro-processor based control in a model of water circulation system in baggasse fired boiler U1 - T 621.184 R14S PY - 1995/// CY - Ludhiana PB - PAU KW - BOILERS KW - MICROPROCESSOR KW - MILLING KW - PROCESSING KW - RICE N2 - It was found that the capacity utilisation was 6.70% in mini rice mills, 9.38% in composite unit, 12.50% in battery of hullers, 42.50% in hullers and 13.40% in integrated paddy processing complex. 78.54% in 2t/hr mills, 96.82% in 3 t/hr mills and 136.77 % ER -